分类:

插装阀

压力控制阀

减压阀


MPRDB


Features Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions

邮箱:sales@meric.cn

产品详情


MPRDBMPRDB

Specifications
Operating Pressure 350BAR
Flow 40L/min
Pilot Flow 0.11 - 0.16L/min
Temperature -30°C to +120°C(-22°F to+250°F)
Cavity T-11A see page K-2
Fluids Mineral-based fluids with viscosities of 7.4 to 420 cSt.
Features
Full reverse flow from reduced pressure (port 1) to inlet (port 2) may
cause the main spool to close. If reverse free flow is required in the
circuit, consider adding a separate check valve to the circuit
Direct acting concept provides highly reliable operation in
contaminated systems, especially at dead headed conditions
Operation
Direct-acting, pressure reducing/relieving Valve reduce a high primary
pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a
full-flow relief function from port 1 to tank (port 3). These Valves incorporate
a damped construction for stable operation allowing the use of high reduced
pressure.